Miniature Profile Ball Rail Installation

REFERENCE SURFACE HEIGHT AND CHAMFERED

To avoid any interference, the corner of the reference edge should have a chamfer. If not, please refer to the following table for the height of the reference edge corner and the height of the reference edge.

THE MOUNTING SURFACE

Surface roughness – the mounting surface should be ground or fine milled to reach a surface roughness Ra1.6.

SCREW TIGHTENING TORQUE (Nm)

GEOMETRIC AND POSITIONAL ACCURACY OF THE MOUNTING SURFACE

Inaccurate mounting surfaces will affect the operational accuracy of the linear guide. The rating lifetime will also be shortened. Insure the mounting surface height differential is greater than the values calculated by the formulas below.

REFERENCE SURFACE

Rail: Both sides of the track rail can be the reference surface without any special marking.

Block: Reference edge is opposite to the groove marking side.

Figure 1